Copper Foil Shielding Tape

Copper Foil Tape EMI Shielding

Copper Foil Tape EMI Shielding

  • Backing: copper foil, 18um / 25um / 35um / 50um reference options
  • Adhesive: conductive acrylic adhesive for through-layer contact
  • Total thickness: 0.05mm-0.12mm typical range
  • Surface: natural copper with paper or PET release liner
  • Width: 3mm-380mm slit width, +/-0.5mm reference tolerance
  • Use: EMI/RFI shielding, grounding, seam bridging and cable wrap

Contact Us

High Heat Tape Company is a manufacturer of copper foil tape emi shielding for electronic assemblies that need reliable grounding paths across seams, overlaps, PCB pads and wrapped cable sections. This conductive copper foil shielding tape combines copper foil with conductive acrylic adhesive, helping electrical contact pass through the bond line instead of relying only on the exposed metal surface. It is made for electronic enclosure seams, control cabinets, communication equipment and shielded room joints where contact resistance and shielding continuity need to be checked on the real assembly.

Product Photos

Technical Data Sheet

Item

Typical Value

Product type

Copper foil tape for EMI/RFI shielding

Backing material

Rolled or electrolytic copper foil

Copper foil thickness

18um / 25um / 35um / 50um reference options

Adhesive system

Conductive acrylic pressure-sensitive adhesive

Total thickness

0.05mm-0.12mm typical

Release liner

Paper or PET liner for slitting and die cutting

Common slit width

3mm-380mm

Width tolerance

+/-0.5mm reference for standard slit rolls

Roll length

20m / 25m / 50m or production reference length

Contact resistance

Test-method dependent, checked across overlap and grounding area

Suggested seam overlap

5mm-10mm starting reference for continuity check

Surface condition before use

Clean, dry, oil-free, coating compatibility checked

Application pressure

Firm roller pressure recommended for adhesive wet-out

Short-term temperature reference

Up to 120C depending on assembly condition

Aging observation reference

60C and 90% RH for 72h, observe lift, discoloration and resistance drift

Die-cut quality check

Clean edge, low burr, controlled adhesive overflow

Main use

Electronic enclosure seams, PCB grounding, cable shielding, control cabinet joints

Shielding performance note

Final result depends on device structure, frequency, grounding and contact quality

 

Benefits

  • Helps maintain shielding continuity across enclosure seams, cabinet joints and lapped copper sections.
  • Conductive adhesive supports electrical contact through the adhesive layer, not only across the copper face.
  • Works for copper foil patches on PCB grounding pads, repair shielding zones and narrow conductive areas.
  • Can be slit from 3mm to 380mm for frame edges, cable termination areas and shielded room panel seams.
  • +/-0.5mm reference width tolerance supports narrow placement on grounding pads or enclosure borders.
  • Helps reduce weak points caused by small gaps, painted surfaces, uneven overlaps or poor surface contact.
  • Clean die-cut edge control helps reduce loose copper burrs and improves placement consistency on small pads.
  • 05mm-0.12mm total thickness options support flat panels, curved cable wrapping and compact modules.

Applications

  1. Electronic enclosure seam shielding for metal or plated plastic housings.
  2. PCB grounding pads, repair shielding patches and conductive surface bridges.
  3. Cable wrapping where the shielding layer needs 5mm-10mm overlap and grounding continuity.
  4. Shielded room panel seams where continuous conductive contact is required.
  5. Control cabinet joints, access doors and removable cover grounding areas.
  6. Communication equipment, RF modules and electronic sub-assemblies with narrow conductive zones.
  7. Die-cut copper foil parts for narrow frames, connector areas and grounding tabs where low burr edges are important.

How does overlap conductivity help maintain EMI/RFI shielding continuity?

Overlap conductivity matters because many EMI/RFI shielding problems do not appear on the flat copper surface. They appear at seams, joints, wrapped edges and grounding transitions. When conductive adhesive is used, the adhesive layer can help create an electrical path through the bond line and across the overlap area. This supports shielding continuity around electronic enclosure seams, PCB grounding points, cable shielding terminations, shielded room joints and communication equipment covers. The final result still depends on surface cleanliness, contact pressure, overlap length and grounding design, so a fixed shielding value should not be claimed without assembly-level testing.If the copper foil is also expected to carry continuous current, use a current-capacity calculation and assembly-level temperature-rise test rather than treating overlap resistance as an amp rating. A practical check is to measure contact resistance across the overlap after pressing and again after dwell time.

Product Overview

This copper foil tape emi shielding product is designed for EMI/RFI control work where a general copper tape would not give enough application confidence. In electronic housings, control cabinet doors, PCB grounding areas and shielded room seams, leakage usually starts around joints, apertures, painted edges and overlapped sections. The tape helps bridge these weak areas with a conductive copper surface and a conductive adhesive layer, giving the finished assembly a more continuous grounding path.

High Heat Tape Company prepares the material in roll, sheet and die-cut formats for enclosure panels, PCB pads, narrow frame edges and cable shielding termination areas. Copper foil thickness can be selected from 18um, 25um, 35um and 50um reference options. Thinner foil wraps more easily around cable curves, while thicker foil gives better handling strength for flat panel seams and wider conductive bridges. For seam work, a 5mm-10mm overlap is often used as a practical starting point, but the final result should be confirmed on the actual device because coating type, contact pressure, grounding layout and frequency condition all affect shielding behavior.

This EMI/RFI conductive adhesive tape is not intended to replace insulation tape, craft copper tape or household repair tape. Its value is in conductive surface bridging. During sample checks, production teams normally look at adhesive wet-out after dwell time, resistance across the overlap after firm pressing, edge lift near corners and copper discoloration after heat-humidity observation. For die-cut parts, the release liner helps handling during placement, while cleaner edges reduce copper burrs, adhesive overflow and uneven corners on PCB grounding pads or electronic enclosure seams.

What should be checked before applying copper foil tape emi shielding to electronic assemblies?

Before copper foil tape emi shielding is used in production, the check should focus on the real assembly, not only the tape roll. Electronic housings, PCB grounding pads, cable wraps and control cabinet seams may all have different coatings, pressure levels and contact areas. A useful inspection includes adhesive wet-out, overlap width, contact resistance after pressing, edge lift after dwell time and visible copper oxidation after heat-humidity exposure. For die-cut parts, clean cut edges are also important because loose copper burrs, adhesive overflow or uneven corners can affect placement on narrow grounding zones. This helps the shielding layer work as a controlled conductive path instead of a simple metal cover.

FAQ

Is this product the same as ordinary copper tape?

No. It is designed for EMI/RFI shielding, grounding continuity and conductive overlap areas, not general household, garden or craft use.

Can it be used as electrical insulation tape?

No. Copper foil and conductive adhesive are intended for conductive shielding paths, not insulation.

Can you guarantee a fixed shielding dB value?

No fixed dB value should be claimed without assembly-level testing. Shielding depends on device structure, grounding, surface contact and frequency.

Can the tape be die-cut for PCB or enclosure use?

Yes. It can be slit or die-cut for grounding pads, enclosure seams, cable termination areas and narrow conductive bridges.